SonicOS/X 7 Device AppFlow

Configuring NetFlow Version 5

To configure Netflow version 5 flow reporting

  1. Click Settings.
  2. For Report Connections in the Settings section, select one of these radio buttons:

    • All (default).
    • Interface-based: when enabled, the flows reported are based on the initiator or responder interface.
    • Firewall/App Rules-based: when enabled, the flows reported are based on already existing firewall rules.

    When enabled, the flows reported are based on the initiator or responder interface or on already existing firewall rules.

    This step is optional, but is required if flow reporting is done on selected interfaces.

  3. Click the External Collector tab.
  4. Select Send Flows and Real-Time Data To External Collector.
  5. Select Netflow version-5 as the External Flow Reporting Format from the drop-down menu.
  6. Specify the External Collector’s IP address in the provided field.
  7. Optionally, for the Source IP to Use for Collector on a VPN Tunnel, specify the source IP if the external collector must be reached by a VPN tunnel.

    This step is required if the external collector must be reached by a VPN tunnel.

  8. Specify the External Collector’s UDP port number in the provided field. The default port is 2055.
  9. Click Accept.

    You might need to reboot the device to completely enable this configuration.