Following an upgrade to firmware SonicOS 7.2.0, customers have reported being unable to save configuration settings on SFP interfaces. Attempting to assign an IP address, change the interface mode, or modify any setting within the Advanced tab results in the error message: "flow-control" is not a reasonable value’. This issue is limited to SFP interfaces and does not affect non-SFP interfaces. This error was not observed on firmware versions prior to SonicOS 7.2.0

As a workaround,
> config ← Hit Enterconfig(2CB8ED828D68)# interface X16 ← Replace X16 with your interface nameconfig(2CB8ED828D68)# ip-assignment WAN static ← Replace WAN with the actual zone (edit-WAN-static[X16])# ip 60.60.60.60 netmask 255.255.255.0 ← Replace with your actual IP info(edit-WAN-static[X16])# commit
2. Ensure a device is physically connected to the SFP interface before attempting to apply configuration changes. Proceed with the following steps:
![]()


If the issue persists, please contact SonicWall Technical Support for further assistance.