SonicOS 8 Device AppFlow

Configuring IPFIX (NetFlow Version 10)

To configure IPFIX (NetFlow version 10) flow reporting

  1. Navigate to DEVICE | AppFlow > Flow Reporting.
  2. Click the Settings tab.
  3. In the Settings section, for Report Connections, select All (default). To limit which flows the firewall reports, select Interface-based or Firewall/App Rules-based instead. For more information, see Settings Configuration.

  4. Click the External Collector tab.
  5. Turn on Send Flows and Real-Time Data To External Collector.

    After you turn on this option, you might need to restart the firewall for the change to take full effect.

  6. From the External Flow Reporting Format drop-down menu, select IPFIX.
  7. For External Collector’s Server Address, select IP and enter the IP address of the external collector.
  8. If the external collector is reached through a VPN tunnel, specify the source IP in Source IP To Use For Collector On A VPN tunnel.
  9. Specify the External Collector’s UDP Port Number in the provided field. The default port is 2055.
  10. In Actions, click Generate ALL Templates. A message requesting confirmation appears.

    Wait for the confirmation (generation takes up to two minutes).

    IPFIX uses templates that the external collector must know before the firewall sends data.

  11. After the templates are generated, click Accept.