SonicOS 8 Device AppFlow

Configuring IPFIX with Extensions

To configure IPFIX with extensions flow reporting

  1. Navigate to DEVICE | AppFlow > Flow Reporting.
  2. Click the Settings tab.
  3. In the Settings section, for Report Connections, select All (default). To limit which flows the firewall reports, select Interface-based or Firewall/App Rules-based instead. For more information, see Settings Configuration.

  4. Click the External Collector tab.
  5. Turn on Send Flows and Real-Time Data To External Collector.

    After you turn on this option, you might need to restart the firewall for the change to take full effect.

  6. From the External Flow Reporting Format drop-down menu, select IPFIX with extensions.
  7. For External Collector’s Server Address, select IP and enter the IP address of the external collector.
  8. If the external collector is reached through a VPN tunnel, specify the source IP in Source IP To Use For Collector On A VPN tunnel.
  9. Specify the External Collector’s UDP Port Number in the provided field. The default port is 2055.
  10. Select the tables you want to receive static flows for from the Send Static AppFlow For Following Tables drop-down menu.
  11. Select the tables you want to receive dynamic flows for from the Send Dynamic AppFlow For Following Tables drop-down menu.
  12. From the Include Following Additional Reports via IPFIX drop-down menu, select any additional reports to export.

    To have the firewall generate system logs, you must select System Logs from this drop-down menu.

  13. Click Generate ALL Templates to generate the templates. Wait for the confirmation (generation takes up to two minutes).

    IPFIX with extensions uses templates that the external collector must know before the firewall sends data.

  14. Turn on Send Static AppFlow At Regular Interval.
  15. Click Generate Static AppFlow Data to generate the static flow data. A message requesting confirmation appears.
  16. To send log messages to the external collector, click Send All Entries next to Send Log Settings To External Collector.

    Ensure that the connection between SonicOS on the firewall and the external collector is ready before you click Send All Entries.

    The external collector loads these properties (see Saved Properties) and settings when it restarts. To synchronize the settings, click Send All Entries when:

    • SonicOS is upgraded and has new log events.
    • The connection between SonicOS (firewall) and the external collector has been down for some time and log settings might have been edited during that time.

    SonicOS sends updates to the external collector automatically if some fields of log event settings change.

  17. Click Accept.
Saved Properties
Category Property
Event properties and settings Event ID
Belongs to group ID
Color
Message type ID
Priority
Stream filter
Event name
Log message
Group properties Group ID
Belongs to category ID
Group name
Category properties Category ID Category name
Message type properties Type ID Type name