Error message when trying to acquire and HA pair "Login failed as the serial numbers do not match"

Description

Error message when trying to acquire and HA pair "Login failed as the serial numbers do not match"

Resolution

Applies to:

All Sonicwall UTM appliances in HA pair


Problem Description:

Error message when attempting to register SonicWall devices in an HA pair with GMS: "Login failed as the serial numbers do not match"

Resolution/Workaround:

Step 1: Make sure you are using the serial number for the primary unit only. You do not need to add the serial number for the backup unit in GMS.
Step 2: Make sure you are  failed over to the Primary unit before trying to acquire in GMS
Step 3: If you are failed over to the backup unit when completing this process you will get the following error message in GMS "Login failed as the serial numbers do not match".


 

Related Articles

  • Analytics On-Prem vs NSM Feature Matrix
    Read More
  • Analytics On-Prem End of Life and NSM Transition FAQ
    Read More
  • NSM On-Prem: Backups over SCP to Windows OpenSSH Server
    Read More
not finding your answers?