SMB-SSL VPN error: Clock is out of sync with Active Directory server

Description

 

SMB-SSL VPN error: Clock is out of sync with Active Directory server.

Image

Cause

When SRA time is not synchronized with AD, user will not be able to login to the portal. SRA Logs shows: Clock out of sync with AD server.Error at user end: System clock is out of sync with Active Directory. Please contact your administrator.

 

Image

Resolution

Please navigate to System ->Time. Under NTP settings-> NTP server1 :Add the AD server IP. Change the update interval to 60 sec. Now user will be able to login.

 